5.235 yd³
Batch plan
Columns, beams, slabs, and walls make the structural total. Lean concrete (PC) is a separate order. Waste is applied to each. Formwork area is not calculated yet.
Formwork area coming soon. adj_slab_thickness, slab_sides, and perimeter_override are already on the template.
Switching units re-reads the numbers already in the table. It does not convert them. Download the sample that matches the unit you want.
| Level | Type | Mark | Shape | Qty | Width (ft) | Depth | Length / height | Area override | Opening | Adj. slab | Confidence | Formula | Net (yd³) | Status |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 4 × (1.50 × 1.50 × 10.00) = 90.00 ft³ (3.33 yd³) | 3.333 | CONFIRMED | ||||||||||||
| 2 × [π × (1.50/2)² × 10.00] = 35.34 ft³ (1.31 yd³) | 1.309 | CONFIRMED | ||||||||||||
| 4 × [1.00 × (2.00 − 0.50) × 18.00] = 108.00 ft³ (4.00 yd³) | 4.000 | CONFIRMED | ||||||||||||
| 2 × [1.00 × (1.50 − 0.333) × 16.00] = 37.34 ft³ (1.38 yd³) | 1.383 | REVIEW | ||||||||||||
| 1 × [(40.00 × 30.00 − 80.00) × 0.50] = 560.00 ft³ (20.74 yd³) | 20.741 | CONFIRMED | ||||||||||||
| 1 × [area 500.00 × 0.50] = 250.00 ft³ (9.26 yd³) | 9.259 | CONFIRMED | ||||||||||||
| 2 × (1.00 × 1.00 × 8.00) = 16.00 ft³ (0.59 yd³) | 0.593 | CONFIRMED | ||||||||||||
| 1 × [(24.00 × 10.00 − 21.00) × 0.67] = 146.73 ft³ (5.43 yd³) | 5.434 | CONFIRMED | ||||||||||||
| 1 × [(42.00 × 32.00) × 0.33] = 443.52 ft³ (16.43 yd³) | 16.427 | CONFIRMED | ||||||||||||
| 1 × [(20.00 × 20.00) × 0.50] = 200.00 ft³ (7.41 yd³) | 7.407 | CONFIRMED |
Columns
5.235 yd³
Beams
5.383 yd³
Slabs
37.407 yd³
Walls
5.434 yd³
Structural net
53.460 yd³
Structural + 7%
57.202 yd³
Lean concrete / PC net
16.427 yd³
PC + 7%
17.577 yd³
| Level | Columns | Beams | Slabs | Walls | Structural net | Structural order | PC net | PC order |
|---|---|---|---|---|---|---|---|---|
| 1st Floor | 4.642 | 5.383 | 30.000 | 5.434 | 45.460 | 48.642 | 16.427 | 17.577 |
| Roof | 0.593 | 0.000 | 7.407 | 0.000 | 8.000 | 8.560 | 0.000 | 0.000 |
9 confirmed, 1 review, 0 missing, 0 error. Structural raw volume 1443.42 ft³. Lean concrete is not included in the structural total.
The audit button opens the print dialog. Choose Save as PDF. Navigation and the editor stay off the printed pages.
Copy this into your own model. FieldFig does not call an AI API.
You are extracting a concrete volume takeoff from structural drawings only. Read S-series plans, sections, and schedules. Ignore architectural finish dimensions, A-series notes, and FFL. Use structural dimensions and TOS or SSL elevations. Extract annotated text and dimensions only. Never eyeball a length off the drawing. If a value is not printed, leave the cell blank and set confidence to MISSING or REVIEW. Write every length in decimal feet. Example: 12'-6" becomes 12.5, never 12.6. Areas use the same unit squared. Do not pre-deduct the slab from a beam. Put the gross beam depth in depth_or_thickness and the adjacent structural slab thickness in adj_slab_thickness. FieldFig subtracts them and checks that the remainder is positive. Column length_or_height is floor-to-floor height, top of slab to top of slab, including the beam-column joint. Beam length_or_height is the clear span, face of column to face of column. If you only have a grid centerline length, write centerline in notes and set confidence to REVIEW. Slab area is width times length_or_height unless a printed area is copied into area_override. Put stair, shaft, and other openings in opening_area. Do not subtract beams, columns, or walls from the slab area. WALL is a structural wall. width is thickness. depth_or_thickness is clear height to the beam or slab soffit. length_or_height is the horizontal length. Put door and window openings in opening_area. Use area_override only for a printed elevation area. PC is lean, blinding, or mud-slab concrete under a foundation. Use the same area and thickness fields as a slab. Do not add PC into the structural concrete total. It is ordered separately. Round columns: shape = ROUND and width = diameter. Other columns: shape = RECT. Always fill mark and source_sheet. Use confidence CONFIRMED only when every geometry cell came from a printed dimension. Output one RFC-4180 CSV with this header: level,element_type,mark,shape,qty,width,depth_or_thickness,length_or_height,area_override,opening_area,adj_slab_thickness,slab_sides,perimeter_override,source_sheet,confidence,notes Under the CSV, add a Discrepancy and Review Checklist for blurry callouts, duplicate marks, and dimensions that disagree.
Concrete volume calculation sheet
Nov 27, 2026 · US yd³ · Waste 7% · Deduction rule Column > Beam > Slab
| Level | Type | Mark | Qty | Dimensions / deduction | Formula | Net volume | Sheet | Status |
|---|---|---|---|---|---|---|---|---|
| 1st Floor | COLUMN | C1 | 4 | Floor to floor, TOS to TOS | 4 × (1.50 × 1.50 × 10.00) = 90.00 ft³ (3.33 yd³) | 3.333 yd³ | S2.01 | CONFIRMED |
| 1st Floor | COLUMN | C2 | 2 | Width is diameter | 2 × [π × (1.50/2)² × 10.00] = 35.34 ft³ (1.31 yd³) | 1.309 yd³ | S2.01 | CONFIRMED |
| 1st Floor | BEAM | B1 | 4 | Clear span, gross depth | 4 × [1.00 × (2.00 − 0.50) × 18.00] = 108.00 ft³ (4.00 yd³) | 4.000 yd³ | S2.02 | CONFIRMED |
| 1st Floor | BEAM | B2 | 2 | Length taken from grid centerlines. Confirm clear span. | 2 × [1.00 × (1.50 − 0.333) × 16.00] = 37.34 ft³ (1.38 yd³) | 1.383 yd³ | S2.02 | REVIEW |
| 1st Floor | SLAB | S1 | 1 | Opening is the stair | 1 × [(40.00 × 30.00 − 80.00) × 0.50] = 560.00 ft³ (20.74 yd³) | 20.741 yd³ | S2.03 | CONFIRMED |
| 1st Floor | SLAB | S2 | 1 | Area taken from the schedule | 1 × [area 500.00 × 0.50] = 250.00 ft³ (9.26 yd³) | 9.259 yd³ | S2.03 | CONFIRMED |
| Roof | COLUMN | C3 | 2 | 2 × (1.00 × 1.00 × 8.00) = 16.00 ft³ (0.59 yd³) | 0.593 yd³ | S3.01 | CONFIRMED | |
| 1st Floor | WALL | W1 | 1 | Door opening deducted from the elevation | 1 × [(24.00 × 10.00 − 21.00) × 0.67] = 146.73 ft³ (5.43 yd³) | 5.434 yd³ | S2.04 | CONFIRMED |
| 1st Floor | PC | PC1 | 1 | Lean concrete under the foundation, not structural | 1 × [(42.00 × 32.00) × 0.33] = 443.52 ft³ (16.43 yd³) | 16.427 yd³ | S1.01 | CONFIRMED |
| Roof | SLAB | S3 | 1 | 1 × [(20.00 × 20.00) × 0.50] = 200.00 ft³ (7.41 yd³) | 7.407 yd³ | S3.01 | CONFIRMED |
| Columns | 5.235 yd³ |
| Beams | 5.383 yd³ |
| Slabs | 37.407 yd³ |
| Walls | 5.434 yd³ |
| Structural net | 53.460 yd³ |
| Structural order including waste | 57.202 yd³ |
| Lean concrete / PC net | 16.427 yd³ |
| Lean concrete / PC order including waste | 17.577 yd³ |
| Level | Structural net | Structural order | PC net | PC order |
|---|---|---|---|---|
| 1st Floor | 45.460 | 48.642 | 16.427 | 17.577 |
| Roof | 8.000 | 8.560 | 0.000 | 0.000 |
Prepared by _______________Checked by _______________Date _______________
Prepared with FieldFig
Columns are full height. Beams are clear span with the adjacent slab deducted. Walls use net elevation area times thickness. Slabs use net plan area and do not deduct beams, columns, or walls. Lean concrete (PC) is ordered separately from structural concrete. Estimating aid only.
level,element_type,mark,shape,qty,width,depth_or_thickness,length_or_height,area_override,opening_area,adj_slab_thickness,slab_sides,perimeter_override,source_sheet,confidence,notes
Column volume uses the full floor-to-floor height. Beam volume uses the clear span and gross depth minus the adjacent slab. Wall volume is net elevation area times thickness. Slab volume uses net plan area times thickness, and does not subtract columns, beams, or walls. Lean concrete (PC) uses the same area math as a slab and is totaled apart from structural concrete.
These run on your machine before the CSV is filled. FieldFig does not bundle them.
| Tool | License | Use |
|---|---|---|
| ezdxf | MIT | Layers, text, dimensions, and polylines from DXF. Convert DWG in your CAD tool first. LibreDWG is GPL-3.0. |
| pdfplumber | MIT | Vector PDF schedules and positioned text. |
| pypdf | BSD-3-Clause | Lightweight PDF text extraction. |
| pypdfium2 | Apache-2.0 / BSD-3-Clause | Render a schedule crop at 300 DPI. |
| PaddleOCR | Apache-2.0 | Local OCR on those crops. |