Skip to content

Concrete volume

Batch plan

Concrete volume takeoff from CSV

Columns, beams, slabs, and walls make the structural total. Lean concrete (PC) is a separate order. Waste is applied to each. Formwork area is not calculated yet.

Formwork area coming soon. adj_slab_thickness, slab_sides, and perimeter_override are already on the template.

  1. 1. Get the template. Download the sample CSV or copy the drawing prompt.
  2. 2. Fill it from the drawings. Use your own model or a local extractor. Do not guess a dimension that is not printed.
  3. 3. Drop the CSV here. Net volume and the ready-mix order update as you edit.

Switching units re-reads the numbers already in the table. It does not convert them. Download the sample that matches the unit you want.

LevelTypeMarkShapeQtyWidth (ft)DepthLength / heightArea overrideOpeningAdj. slabConfidenceFormulaNet (yd³)Status
4 × (1.50 × 1.50 × 10.00) = 90.00 ft³ (3.33 yd³)3.333CONFIRMED
2 × [π × (1.50/2)² × 10.00] = 35.34 ft³ (1.31 yd³)1.309CONFIRMED
4 × [1.00 × (2.00 − 0.50) × 18.00] = 108.00 ft³ (4.00 yd³)4.000CONFIRMED
2 × [1.00 × (1.50 − 0.333) × 16.00] = 37.34 ft³ (1.38 yd³)1.383REVIEW
1 × [(40.00 × 30.00 − 80.00) × 0.50] = 560.00 ft³ (20.74 yd³)20.741CONFIRMED
1 × [area 500.00 × 0.50] = 250.00 ft³ (9.26 yd³)9.259CONFIRMED
2 × (1.00 × 1.00 × 8.00) = 16.00 ft³ (0.59 yd³)0.593CONFIRMED
1 × [(24.00 × 10.00 − 21.00) × 0.67] = 146.73 ft³ (5.43 yd³)5.434CONFIRMED
1 × [(42.00 × 32.00) × 0.33] = 443.52 ft³ (16.43 yd³)16.427CONFIRMED
1 × [(20.00 × 20.00) × 0.50] = 200.00 ft³ (7.41 yd³)7.407CONFIRMED

Columns

5.235 yd³

Beams

5.383 yd³

Slabs

37.407 yd³

Walls

5.434 yd³

Structural net

53.460 yd³

Structural + 7%

57.202 yd³

Lean concrete / PC net

16.427 yd³

PC + 7%

17.577 yd³

LevelColumnsBeamsSlabsWallsStructural netStructural orderPC netPC order
1st Floor4.6425.38330.0005.43445.46048.64216.42717.577
Roof0.5930.0007.4070.0008.0008.5600.0000.000

9 confirmed, 1 review, 0 missing, 0 error. Structural raw volume 1443.42 ft³. Lean concrete is not included in the structural total.

The audit button opens the print dialog. Choose Save as PDF. Navigation and the editor stay off the printed pages.

AI drawing-to-CSV prompt

Copy this into your own model. FieldFig does not call an AI API.

You are extracting a concrete volume takeoff from structural drawings only.
Read S-series plans, sections, and schedules. Ignore architectural finish dimensions, A-series notes, and FFL. Use structural dimensions and TOS or SSL elevations.
Extract annotated text and dimensions only. Never eyeball a length off the drawing. If a value is not printed, leave the cell blank and set confidence to MISSING or REVIEW.
Write every length in decimal feet. Example: 12'-6" becomes 12.5, never 12.6. Areas use the same unit squared.
Do not pre-deduct the slab from a beam. Put the gross beam depth in depth_or_thickness and the adjacent structural slab thickness in adj_slab_thickness. FieldFig subtracts them and checks that the remainder is positive.
Column length_or_height is floor-to-floor height, top of slab to top of slab, including the beam-column joint.
Beam length_or_height is the clear span, face of column to face of column. If you only have a grid centerline length, write centerline in notes and set confidence to REVIEW.
Slab area is width times length_or_height unless a printed area is copied into area_override. Put stair, shaft, and other openings in opening_area. Do not subtract beams, columns, or walls from the slab area.
WALL is a structural wall. width is thickness. depth_or_thickness is clear height to the beam or slab soffit. length_or_height is the horizontal length. Put door and window openings in opening_area. Use area_override only for a printed elevation area.
PC is lean, blinding, or mud-slab concrete under a foundation. Use the same area and thickness fields as a slab. Do not add PC into the structural concrete total. It is ordered separately.
Round columns: shape = ROUND and width = diameter. Other columns: shape = RECT.
Always fill mark and source_sheet. Use confidence CONFIRMED only when every geometry cell came from a printed dimension.
Output one RFC-4180 CSV with this header: level,element_type,mark,shape,qty,width,depth_or_thickness,length_or_height,area_override,opening_area,adj_slab_thickness,slab_sides,perimeter_override,source_sheet,confidence,notes
Under the CSV, add a Discrepancy and Review Checklist for blurry callouts, duplicate marks, and dimensions that disagree.

Concrete volume calculation sheet

Concrete Volume Takeoff

Nov 27, 2026 · US yd³ · Waste 7% · Deduction rule Column > Beam > Slab

LevelTypeMarkQtyDimensions / deductionFormulaNet volumeSheetStatus
1st FloorCOLUMNC14Floor to floor, TOS to TOS4 × (1.50 × 1.50 × 10.00) = 90.00 ft³ (3.33 yd³)3.333 yd³S2.01CONFIRMED
1st FloorCOLUMNC22Width is diameter2 × [π × (1.50/2)² × 10.00] = 35.34 ft³ (1.31 yd³)1.309 yd³S2.01CONFIRMED
1st FloorBEAMB14Clear span, gross depth4 × [1.00 × (2.00 − 0.50) × 18.00] = 108.00 ft³ (4.00 yd³)4.000 yd³S2.02CONFIRMED
1st FloorBEAMB22Length taken from grid centerlines. Confirm clear span.2 × [1.00 × (1.50 − 0.333) × 16.00] = 37.34 ft³ (1.38 yd³)1.383 yd³S2.02REVIEW
1st FloorSLABS11Opening is the stair1 × [(40.00 × 30.00 − 80.00) × 0.50] = 560.00 ft³ (20.74 yd³)20.741 yd³S2.03CONFIRMED
1st FloorSLABS21Area taken from the schedule1 × [area 500.00 × 0.50] = 250.00 ft³ (9.26 yd³)9.259 yd³S2.03CONFIRMED
RoofCOLUMNC322 × (1.00 × 1.00 × 8.00) = 16.00 ft³ (0.59 yd³)0.593 yd³S3.01CONFIRMED
1st FloorWALLW11Door opening deducted from the elevation1 × [(24.00 × 10.00 − 21.00) × 0.67] = 146.73 ft³ (5.43 yd³)5.434 yd³S2.04CONFIRMED
1st FloorPCPC11Lean concrete under the foundation, not structural1 × [(42.00 × 32.00) × 0.33] = 443.52 ft³ (16.43 yd³)16.427 yd³S1.01CONFIRMED
RoofSLABS311 × [(20.00 × 20.00) × 0.50] = 200.00 ft³ (7.41 yd³)7.407 yd³S3.01CONFIRMED

Totals

Columns5.235 yd³
Beams5.383 yd³
Slabs37.407 yd³
Walls5.434 yd³
Structural net53.460 yd³
Structural order including waste57.202 yd³
Lean concrete / PC net16.427 yd³
Lean concrete / PC order including waste17.577 yd³

By level

LevelStructural netStructural orderPC netPC order
1st Floor45.46048.64216.42717.577
Roof8.0008.5600.0000.000

Items flagged for reviewer check

  • REVIEW · B2 · S2.02 · Length taken from grid centerlines. Confirm clear span.

Prepared by _______________Checked by _______________Date _______________

Prepared with FieldFig

Columns are full height. Beams are clear span with the adjacent slab deducted. Walls use net elevation area times thickness. Slabs use net plan area and do not deduct beams, columns, or walls. Lean concrete (PC) is ordered separately from structural concrete. Estimating aid only.

level,element_type,mark,shape,qty,width,depth_or_thickness,length_or_height,area_override,opening_area,adj_slab_thickness,slab_sides,perimeter_override,source_sheet,confidence,notes

Deduction rule

Column volume uses the full floor-to-floor height. Beam volume uses the clear span and gross depth minus the adjacent slab. Wall volume is net elevation area times thickness. Slab volume uses net plan area times thickness, and does not subtract columns, beams, or walls. Lean concrete (PC) uses the same area math as a slab and is totaled apart from structural concrete.

  • Centerline beam length counts the joint that already sits inside the column. Use the clear span, or mark the row REVIEW.
  • A beam depth that still includes the slab double-counts that band. Leave the depth gross and fill adj_slab_thickness.
  • Architectural FFL is not a structural thickness. Use the structural slab and TOS elevations.
  • Openings and drop panels change the slab. Put openings in opening_area. Do not hide a drop panel inside the waste percent.

Local drawing tools

These run on your machine before the CSV is filled. FieldFig does not bundle them.

ToolLicenseUse
ezdxfMITLayers, text, dimensions, and polylines from DXF. Convert DWG in your CAD tool first. LibreDWG is GPL-3.0.
pdfplumberMITVector PDF schedules and positioned text.
pypdfBSD-3-ClauseLightweight PDF text extraction.
pypdfium2Apache-2.0 / BSD-3-ClauseRender a schedule crop at 300 DPI.
PaddleOCRApache-2.0Local OCR on those crops.

PyMuPDF is AGPL-3.0 and poppler-utils is GPL-2.0. Both are useful in a personal script. Read the license before you ship them inside a commercial product.